Mood light for a X-Ray System

Request Number

NG_2017_0013_N_015
Point of Contact
Need was closed on
Aug 8
Description

Siemens Healthineers is looking for an illuminated front panel which brings the patient into a more relaxed, calm mood during a medical examination.

 

 

Background

To get good pictures of the female breast it will be pressed in a way that feels uncomfortable.

 

So when it comes to treatments or when diagnostic images are made of very sensitive parts of the body it is important that the patients are relaxed during that time. Bringing them into a calm mood is the basis for a good X-ray with high quality pictures. 

 

The actual mood light panel will be part of a medical system which should bring women into a good mood during an uncomfortable breast treatment. 

 

Key success Criteria
  • Illuminated glass or plastic shield (approx. 530x2,000 mm²) with separately controllable white/red/green/blue LEDs
  • Ability to control colors in up to 50 fixed programs, e.g. 1 to 5 colors with defined holding and transition times (e.g. 20s green, 5s transition, 20s magenta, …)
  • Mounted to the stand of the unit in vertical position, selectable combinations, configurable (power input range 110VAc…240VAc) by software installed on work station
  • Should have an interface to TCPIP, USB, RS232 or similar from system work station
  • With an expected  lifetime of 10 years
  • Deviation of light intensity : max 3 cd/m²
  • Heat dissipation: 20W
  • Mains power: 100 W
  • Medical standards are necessary
  • EMV: EN 60601-1-2: 2007 Class B
  • Safety: EN 60601-1: 2007; Installation height 3000m above NN
  • All components shall be RoHS conform

 

Possible Approaches

Any approach for producing such an illuminated panel is welcome.

 

Approaches not of Interest

We are not interested in solutions which require lots of manual work for either processing the panel, control box or the integration of both.

 

Due Date
Sep 30
Items to be submitted

We are looking for concise, non-confidential proposals. The proposal should:

  • Describe the technical approach
  • Include a description of the responding organization or team and their experience.

To respond, please use the Respond button located to the right of this page.

 

Please note that only non-confidential information can be accepted. By submitting a response you represent that the response does not contain and will not be deemed to contain any confidential information of any kind whatsoever.  By submitting a response, you acknowledge that Siemens, in its sole discretion, may select or reject a response or any portion thereof.

 